LUXIFY · THE WALL BEHIND THE STONE
Frame the wall before the stone goes up.
Explore the frame, backer board and stone as separate layers. Rotate the concept in 3D, read the elevation and share preliminary quantities with your professional for review before building.
Preliminary geometry — not for construction. No sizing of studs, headers, connections, anchors or mantel/TV/vanity support loads. Appliance manual, thermal assembly, actual wall and applicable requirements need professional verification before fabrication or installation.
Preparing the wall in 3D…
Drag to turn · scroll or pinch to zoom
- stone weight on the wall
- 16.5 lb/sq ft
- how the stone is held
- Mechanical support concept — not sized
- built wall depth
- 5 1/8″ (+13″ chase)
- framing pieces
- 34
- stone on this wall
- 1,046 lb
Assumed weight screening rule
This tool uses 15 lb/sq ft only as a preliminary weight-screening assumption. Being below it does not approve bonding; being above it flags mechanical support for design. Panel dimensions, substrate, anchors, mortar, heat, moisture, manufacturer instructions and applicable local requirements still need project-specific professional verification.
Check before you build
- The 3 cm stone weighs 16.5 lb/sq ft, above this model’s 15 lb/sq ft screening threshold. Mechanical support requires project-specific design; this is not an installation approval.
- Direct-vent gas: A sealed chamber takes outside air in and sends exhaust out through the same duct. The most widely accepted. Minimum wall depth 18″.
- It needs a hole in the exterior wall and the duct path INSIDE the framing: the stud depth has to accommodate it.
- Depth: the built wall gives 5.2″ (stud 3.5 + board 0.5 + stone 1.2) and the appliance needs 18″. You are 13″ short: bring the wall forward as a projecting chase, or recess the appliance into the existing wall cavity behind it. Do not try to fit it inside the stud bay.
- Every appliance manual gives the FRAMING OPENING and the CLEARANCES TO COMBUSTIBLES, including the minimum clear height above the opening before a wood mantel. Those numbers come from the appliance manufacturer, not from here. This tool reserves the opening you enter and draws the framing around it.
Next steps
WhatsApp is a separate conversation from this page. You can ask for a person on our team there. Preliminary geometry — not for construction. No sizing of studs, headers, connections, anchors or mantel/TV/vanity support loads. Appliance manual, thermal assembly, actual wall and applicable requirements need professional verification before fabrication or installation.